Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Prosthet Dent ; 130(5): 780-785, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35184888

RESUMO

STATEMENT OF PROBLEM: Conventional analog methods have been replaced with digital methods for removable partial denture (RPD) frameworks. However, limited information is available regarding the build direction of RPD frameworks and its effect on properties. PURPOSE: The purpose of this in vitro study was to evaluate the mechanical and surface properties of the cobalt chromium (Co-Cr) alloy produced at different build angles by the laser powder bed fusion additive manufacturing (AM) technology used for RPD framework fabrication. MATERIAL AND METHODS: Plate-shaped Co-Cr specimens (n=6) were produced by the AM technology and divided into 3 groups depending on the build angle (0, 45, or 90 degrees). The elastic modulus and fracture properties were evaluated by flexural testing. Additionally, 15 disks were printed by using the same parameters of the plates (n=5) to analyze the surface hardness with microhardness testing, and surface properties were determined by surface free energy by using the contact angle and surface roughness measured by using a profilometer. Twelve Co-Cr cylindrical specimens were produced by using the same parameters (n=4), and their microstructure was examined by using an optical microscope. One-way ANOVA was used to evaluate the overall effects of the interaction between groups, and the Tukey test was applied when the interaction was statistically significant (α=.05). RESULTS: The flexural strength showed a statistically significant difference (P<.05), with the peak value exhibited by the 0-degree group. A statistical difference was also observed between the angulation and modulus of elasticity; however, the highest value was exhibited by the 45-degree group. For the fracture topography, all groups observed a dimple-like fracture, although the 45-degree group showed wider cleavage planes of fractures than other angulations. For microhardness, the 0- and 45-degree groups exhibited a statistical difference in relation to the 90-degree group (P<.05). For surface properties, no statistically significant difference (P>.05) was found in any of the evaluated parameters. Dependence on the build angles was evidenced by the molten pool boundaries during observation of the microstructure. CONCLUSIONS: The build angle influenced the flexural strength and microhardness of the Co-Cr alloy produced by AM; however, it does not affect surface free energy and surface roughness.


Assuntos
Prótese Parcial Removível , Ligas de Cromo/química , Elasticidade , Módulo de Elasticidade , Propriedades de Superfície , Teste de Materiais
2.
Braz. arch. biol. technol ; 62: e19170775, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1011522

RESUMO

Abstract Tissue engineering suggests different forms to reconstruct tissues and organs. One of the ways is through the use of polymeric biomaterials such as poly(L-lactic acid) (PLLA). PLLA is a recognized material in tissue engineering due to its characteristics as biocompatibility and bioresorbability. In this work PLLA fibrous membranes were produced by a simple technique known as rotary jet spinning. The rotary jet spinning consists of fibrous membranes production, with fibers of scale nano/micrometric, from a polymeric solution through the centrifugal force generated by the equipment. The membranes formed were subjected to preliminary in vitro assays to verify the cytotoxicity of the membranes made in contact with the cells. Direct cytotoxicity assays were performed through the MTT, AlamarBlue® and Live/Dead® tests, with fibroblastic and osteoblastic cells. The results obtained in this study showed that PLLA membranes produced by rotary jet spinning showed promising results in the 24-hours contact period of the cells with the PLLA fibrous membranes. The information presented in this preliminary study provides criteria to be taken in the future procedures that will be performed with the biomaterial produced, aiming at its improvement.


Assuntos
Materiais Biocompatíveis , Ácido Láctico , Engenharia Tecidual/métodos , Técnicas In Vitro/instrumentação
3.
Acta Cir Bras ; 29(9): 579-87, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25252204

RESUMO

PURPOSE: To investigate the osseointegration properties of prototyped implants with tridimensionally interconnected pores made of the Ti6Al4V alloy and the influence of a thin calcium phosphate coating. METHODS: Bilateral critical size calvarial defects were created in thirty Wistar rats and filled with coated and uncoated implants in a randomized fashion. The animals were kept for 15, 45 and 90 days. Implant mechanical integration was evaluated with a push-out test. Bone-implant interface was analyzed using scanning electron microscopy. RESULTS: The maximum force to produce initial displacement of the implants increased during the study period, reaching values around 100N for both types of implants. Intimate contact between bone and implant was present, with progressive bone growth into the pores. No significant differences were seen between coated and uncoated implants. CONCLUSION: Adequate osseointegration can be achieved in calvarial reconstructions using prototyped Ti6Al4V Implants with the described characteristics of surface and porosity.


Assuntos
Cerâmica/uso terapêutico , Implantes Experimentais , Osseointegração/fisiologia , Crânio/cirurgia , Titânio/uso terapêutico , Animais , Fosfatos de Cálcio , Cerâmica/química , Materiais Revestidos Biocompatíveis , Masculino , Teste de Materiais , Microscopia Eletrônica de Varredura , Ratos Wistar , Reprodutibilidade dos Testes , Espectrometria por Raios X , Propriedades de Superfície , Fatores de Tempo , Titânio/química , Resultado do Tratamento
4.
Acta cir. bras ; 29(9): 579-587, 09/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-722127

RESUMO

PURPOSE: To investigate the osseointegration properties of prototyped implants with tridimensionally interconnected pores made of the Ti6Al4V alloy and the influence of a thin calcium phosphate coating. METHODS: Bilateral critical size calvarial defects were created in thirty Wistar rats and filled with coated and uncoated implants in a randomized fashion. The animals were kept for 15, 45 and 90 days. Implant mechanical integration was evaluated with a push-out test. Bone-implant interface was analyzed using scanning electron microscopy. RESULTS: The maximum force to produce initial displacement of the implants increased during the study period, reaching values around 100N for both types of implants. Intimate contact between bone and implant was present, with progressive bone growth into the pores. No significant differences were seen between coated and uncoated implants. CONCLUSION: Adequate osseointegration can be achieved in calvarial reconstructions using prototyped Ti6Al4V Implants with the described characteristics of surface and porosity. .


Assuntos
Animais , Masculino , Cerâmica/uso terapêutico , Implantes Experimentais , Osseointegração/fisiologia , Crânio/cirurgia , Titânio/uso terapêutico , Fosfatos de Cálcio , Materiais Revestidos Biocompatíveis , Cerâmica/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Ratos Wistar , Reprodutibilidade dos Testes , Espectrometria por Raios X , Propriedades de Superfície , Fatores de Tempo , Resultado do Tratamento , Titânio/química
5.
Rev. bras. neurol ; 41(2): 29-35, abr.-jun. 2005. ilus
Artigo em Português | LILACS | ID: lil-502937

RESUMO

Até o aparecimento da tomografia computadorizada, e principalmente, da ressonância magnética, os métodos diagnósticos complementares eram bem limitados na avaliação e, sobretudo na extensão da lesão, tendo então a RM sido preconizada como método de escolha na avaliação neurorradiológica. Exames de imagem como ventriculografia, pneumoencefalografia e radiografia convencional foram deixados de lado em prol destes métodos mais recentes, ao mesmo tempo em que a arteriografia ganhou indicações mais precisas e limitadas. O estudo da espectroscopia permite diagnósticos mais precoses e caracterização de bordas lesionais, com finalidade extremamente prática para neurocirurgiões. É ainda possível determinar e qualificar a perda neuronal, funcionando como importante ferramenta diagnóstica na detecção e prognóstico de doenças neurológicas.


Before the appearance of computed tomography and specially magnetic resonance imaging, complementary exams were limited in the extension's lesion evaluation, so the MRI have been chosen the gold standard for imaging the neurological diseases. Ventriculography, pneumoencefalography and conventional X rays were destined to be forgotten while arteriography secured indications in precise and limited cases. Spectroscopy gives early diagnosis and defines lesion's borders, providing practical information for neurosurgeons. It is also possible to qualify the neuronal loss, representing as an important tool in detection and prognosis for neurological diseases.


Assuntos
Humanos , Diagnóstico por Imagem , Espectroscopia de Ressonância Magnética , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...